Skip Navigation

This Article
Right arrow Extract Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (10)
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Kolstad, H. A.
Right arrow Articles by Mikkelsen, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kolstad, H. A.
Right arrow Articles by Mikkelsen, S.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Epidemiologic Reviews 24:203-217 (2002)
© 2002 by the Johns Hopkins Bloomberg School of Public Health

Do Indoor Molds in Nonindustrial Environments Threaten Workers’ Health? A Review of the Epidemiologic Evidence

Henrik A. Kolstad1,2, Charlotte Brauer2, Martin Iversen3, Torben Sigsgaard4 and Sigurd Mikkelsen2

1 Department of Occupational Medicine, Aarhus University Hospital, Aarhus, Denmark. 2 Department of Occupational Medicine, Glostrup Hospital, University of Copenhagen, Denmark. 3 Department of Lung Diseases, Aarhus University Hospital, Aarhus, Denmark. 4 Institute of Environmental and Occupational Medicine, Aarhus University, Aarhus, Denmark.

Received for publication February 21, 2000; accepted for publication November 21, 2001.


Abbreviations: CFU, colony-forming units; CI, confidence interval.


    INTRODUCTION
 TOP
 INTRODUCTION
 INDOOR MOLDS IN NONINDUSTRIAL...
 LITERATURE SEARCH AND STUDY...
 CASE AND CLUSTER REPORTS
 ANALYTICAL STUDIES
 EXPOSURE-EFFECT RELATIONS
 DISCUSSION
 REFERENCES
 
Since the early 1980s, mucosal, skin, and respiratory symptoms, in addition to general symptoms such as fatigue and headache, have been related to the indoor climate of nonindustrial workplaces. Mold growth has been suggested as a causal factor because the health complaints frequently have been related to indicators of microbial contamination: visible signs of mold growth, moisture, and water damage (1).

Molds refer to growing colonies of different species of fungi. Fungi are nonphotosynthetic plant bodies that are ubiquitous in nature and decompose organic material. The species differ in size, but most are about 10 µm in diameter. Fungi are able to grow at a relative humidity of between 75 percent and 95 percent at normal room temperature. Fungi reproduce by spores that spread by air, depending on climatic factors, activity in the surrounding environment, and physiologic properties of the individual species (2, 3). Growing fungi may produce metabolites to protect a nutrient source from bacteria. Mycotoxins are metabolites that are able to initiate a toxic response in vertebrates when ingested, inhaled, or otherwise absorbed.

Mold antigens may induce an immunoglobulin E–mediated response (4, 5). ß-(1,3)-D-glucan is a polyglucose structure of mold cell walls that can induce inflammatory reactions through a specific receptor (6, 7). Ergosterol is the primary membrane sterol of filamentous fungi, and extracellular polysaccharides are stable carbohydrates secreted during fungal growth. At present, there is no evidence for a pathogenic role of ergosterol or extracellular polysaccharides in allergic or inflammatory reactions to fungal components (8).

High-level exposure to airborne mold spores may cause allergic alveolitis (e.g., farmer’s lung) (9). Aerosols from air humidifiers heavily contaminated by bacteria, algae, or molds may cause inhalation fever (humidifier fever) (10). Single cases of occupational asthma have been attributed to mold exposure (11, 12), and asthma severity has been associated with outdoor mold spore levels in children and adolescents (13). Mold-contaminated food and feed have been held responsible for serious cases of poisoning in humans and livestock (14). It was discussed recently whether mycotoxins may be responsible for cases of acute idiopathic pulmonary hemorrhage in infants (15, 16).

Among employees of nonindustrial workplaces with visible signs of mold growth, moisture, or water damage, there has been an increasing concern about possible health effects. This review evaluates this concern based on present epidemiologic literature. Recently, the topic was partly reviewed by Husman, Verhoeff and Burge, and Peat and Dickerson (1719). However, they focused mainly on the health effects in children, which may not be relevant for the adult working population (20). Furthermore, several studies assessing mold exposure in the sick building syndrome were included to only a limited extent. This is a systematic review of reports on health effects related to mold growth (or indicators of mold growth) in nonindustrial work sites. Since comparable mold exposure is seen in dwellings, studies that related adult health effects to exposure at home were also reviewed (21).


    INDOOR MOLDS IN NONINDUSTRIAL ENVIRONMENTS
 TOP
 INTRODUCTION
 INDOOR MOLDS IN NONINDUSTRIAL...
 LITERATURE SEARCH AND STUDY...
 CASE AND CLUSTER REPORTS
 ANALYTICAL STUDIES
 EXPOSURE-EFFECT RELATIONS
 DISCUSSION
 REFERENCES
 
To assess the possible health effects of indoor molds, characterization of the presence and the degree of exposure is crucial. Use of questionnaire information on visible signs or the characteristic smell of molds or dampness is a simple method, but it gives little information about the degree of exposure and involves a risk of reporting bias (22). Inspection by surveyors can provide a standardized assessment of mold growth in terms of the area affected (23).

Settlement plates, dust samples, and air samples can be used to determine viable mold spores. However, these methods have limitations concerning determination of concentrations of viable mold spores in the air representative of time-weighted exposure (24). Settlement plates have failed to adequately collect small spores and have shown little reproducibility, with average coefficients of variance of about 30 percent regarding the number of colony-forming units (CFUs) (2, 25). Dust sampling has resulted in coefficients of variance of between 11 percent and 27 percent (CFU/g dust), and the mean agreement for species isolated has varied from 37 percent to 60 percent (26). Comparable figures have been reported for air sampling (25).

Viable mold counts may represent only a minor fraction of the total number of fungal particles in indoor air because of different survival rates and difficulties in detecting them on growth agar medium. Nonviable and viable spores can contain allergens and mycotoxins, and it may be of importance also to assess the total number of spores (viable and nonviable), even if a high correlation has been found between viable and total mold counts (27).

Levels of ß-(1,3)-D-glucan, ergosterol, and extracellular polysaccharides may be other appropriate measures of fungal biomass, even if only measures of extracellular polysaccharides provide information on the fungal species (8). Coefficients of variance of 25 percent and 16 percent have been reported for measurements of ß-(1,3)-D-glucan and extracellular polysaccharides, respectively, while relative standard deviations for determining ergosterol have ranged from 5 percent to 27 percent (8, 28, 29).

Total airborne mold counts (viable and nonviable) of 667–570,000 spores/m3 have been reported in dwellings (30, 31). Table 1 presents viable mold exposure levels expressed as CFU per cubic meter (only limited data exist for the other parameters) and shows considerable variation, ranging from 0 to 450,000 CFU/m3, between studies. Furthermore, counts differ by season, and there is a tendency toward higher counts at lower latitudes (in Asia). Generally, viable spore counts are higher outdoors than indoors. Significantly higher counts were reported in buildings with signs of mold growth or dampness than in reference buildings (3234); however, no or small differences in mold levels have also been shown (21, 23, 25, 30, 3537). During remediation of moldy buildings (homes or nonindustrial workplaces), mold exposure levels may increase significantly (38).


View this table:
[in this window]
[in a new window]
 
TABLE 1. Viable mold exposure levels in indoor and outdoor air, in buildings with and without signs of mold growth, and by continent: results from exposure surveys and epidemiologic studies, 1984–2000
 
The predominant mold genera are Penicillium, Cladosporium, and Aspergillus indoors as well as outdoors in all parts of the world. Fungi such as Trichoderma and Stachybotrys, which require high water activity (aw >0.90–0.95) for growth, are infrequent, but high exposure levels may be seen (34). Stachybotrys has been identified more frequently in buildings with mold problems (32, 39, 40).


    LITERATURE SEARCH AND STUDY QUALITY EVALUATION
 TOP
 INTRODUCTION
 INDOOR MOLDS IN NONINDUSTRIAL...
 LITERATURE SEARCH AND STUDY...
 CASE AND CLUSTER REPORTS
 ANALYTICAL STUDIES
 EXPOSURE-EFFECT RELATIONS
 DISCUSSION
 REFERENCES
 
MEDLINE (National Institutes of Health, Bethesda, Maryland) (1968–June 2000) and NIOSHTIC (National Institute for Occupational Safety and Health Technical Information Center; database provided by SilverPlatter Information Ltd., London, United Kingdom) (1977–June 2000) were searched to identify human peer-reviewed studies published in English that related adult health effects to mold exposure in nonindustrial indoor environments. Additional snowball searches were conducted of the bibliographies in the original papers identified initially. A total of 47 articles were identified.

The articles were initially classified as 1) case or cluster reports and 2) analytical studies in populations with no concerns about possible mold-related health effects. The analytical studies were then scored according to six quality parameters, as follows (score value in parentheses): 1) design: cross-sectional (0), longitudinal (1); 2) participation rate: <80 percent (0), >=80 percent (1); 3) exposure assessment: qualitative (0), quantitative, nonindividual measurements (each measurement representing more than one study subject) (1), quantitative, individual measurements (2); 4) health outcome: self-reported symptoms or weakly defined health outcomes (0), self-reported physician-diagnosed disease or well-defined symptoms (1), physician-diagnosed disease or objective findings (2); 5) potential confounders controlled for: no or limited confounder control (0), comprehensive confounder control that included smoking (1); and 6) exposure-response assessment: no (0), yes (1). Finally, each study was assigned a total sum of scores.

Weighted average odds ratios with 95 percent confidence intervals were computed when appropriate (41). The odds ratio values from each study were weighted by the inverse variance extracted from the confidence intervals, and 95 percent confidence intervals for the meta-odds ratios were computed from the sum of the weights.


    CASE AND CLUSTER REPORTS
 TOP
 INTRODUCTION
 INDOOR MOLDS IN NONINDUSTRIAL...
 LITERATURE SEARCH AND STUDY...
 CASE AND CLUSTER REPORTS
 ANALYTICAL STUDIES
 EXPOSURE-EFFECT RELATIONS
 DISCUSSION
 REFERENCES
 
A total of 19 articles were identified that described patient cases with health effects attributed to mold contamination of the indoor environment or cross-sectional studies conducted in populations because of suspected health effects related to mold exposure in those populations.

Three case reports described a teacher, an office worker, and a married couple, all diagnosed with allergic alveolitis attributed to indoor mold exposure at work or at home (4244). High levels of viable airborne molds (approximately 5 x 103 CFU/m3) dominated by Penicillium species originating from a contaminated ventilation system were detected in the workplace of the office worker (43). No quantitative exposure levels were given for the married couple, but they showed precipitating antibodies against Penicillium species detected in their home (44). Precipitating antibodies against Alternaria, Aspergillus, Botrytis, Cladosporium, Penicillium, Pullularia, and Rhizopus were shown in the teacher, but no relevant environmental data were available (42). A case of organic dust toxic syndrome in a museum staff handling moldy books was related with high-level exposure to airborne molds (106 CFU/m3 viable molds and 108/m3 total molds) (45). A cluster of 33 cases of granulomatous lung disease in swimming pool lifeguards was related to endotoxin levels in the work environment, but not with fungal levels (46).

Household aggregation of cold and flu symptoms, sore throat, diarrhea, headache, fatigue, dermatitis, intermittent focal alopecia, and generalized malaise have been related to mold exposure since symptoms were reduced after removal of mold-contaminated material (Penicillium, Trichoderma, Phoma species, and Stachybotrys atra) from the homes (47, 48). In eight of nine cases of allergic fungal sinusitis, identical mold species were identified in the indoor air as isolated in mucin from the maxillary and ethmoid sinuses of the patients (49).

Reduced bronchial hyperresponsiveness was observed in employees following renovation of a day care institution that significantly reduced exposure levels of ß-(1,3)-D-glucan, but this finding was not supported by a study among inhabi-tants of water-damaged homes (50, 51). No consistent associations between ß-(1,3)-D-glucan exposure and inflammatory markers were observed (51).

Among 91 office workers with symptoms thought to be related to the indoor environment, 67 percent showed immunoglobulin G antibodies to one or more of a range of molds, 3 percent showed immunoglobulin E antibodies to Alternaria, but none showed immunoglobulin E antibodies to Penicillium, Candida, or Aspergillus species; however, these findings were unrelated to environmental mold measures (52). An increased sensitivity to Penicillium chrysogenum, S. atra, and Trichoderma viride was observed in an experimental histamine release test in 25 subjects with symptoms of sick building syndrome (53). A reduced number of T lymphocytes in 53 employees of an office contaminated with S. atra was reported, but not in the employees with presumably the highest exposure (40).

Increased prevalences of eye, nose, throat, and lung symptoms and of general symptoms were reported among workers and inhabitants of buildings with signs of indoor mold growth and viable mold levels of about 1,000 CFU/m3 or higher (39, 54) as well as less than 300 CFU/m3 (40, 5557), or they were related to ß-(1,3)-D-glucan level (58).


    ANALYTICAL STUDIES
 TOP
 INTRODUCTION
 INDOOR MOLDS IN NONINDUSTRIAL...
 LITERATURE SEARCH AND STUDY...
 CASE AND CLUSTER REPORTS
 ANALYTICAL STUDIES
 EXPOSURE-EFFECT RELATIONS
 DISCUSSION
 REFERENCES
 
A total of 28 articles based on analytical studies not initiated by concerns about mold-related health effects (or health effects related to other aspects of a sick building) in the study populations were identified. Fifteen studies focused on occupational exposures (35, 5972) (table 2), and 13 examined samples of the general population for health problems related to exposures at home (31, 7384) (table 3).


View this table:
[in this window]
[in a new window]
 
TABLE 2. Epidemiologic studies of health effects related to mold exposure in nonindustrial workplaces, 1990–2000
 

View this table:
[in this window]
[in a new window]
 
TABLE 3. Epidemiologic studies of health effects related to mold growth at home, 1985–1999
 
Design

Except for two longitudinal studies that recorded exacerbations in asthma patients (73) and nasal lavage parameters in school workers (72), all studies used a cross-sectional sampling frame and relied on prevalent symptom reports or case definitions, including the six case-control studies (31, 62, 68, 75, 80, 83). The participation rate was generally high and varied between 57 percent (80) and 100 percent (61, 70).

Mold exposure

The occupational exposure settings included offices (59, 62, 63, 65, 6771), day care centers (60, 61, 66), schools (64, 72), and hospitals (35). Exposure information frequently was based on the study participants’ own reports of mold growth or moisture (60, 66, 71, 7477, 79, 81). In some studies, members of the research team made this assessment (68, 78, 80, 82, 83). Between 5 percent (79) and 75 percent (60) of the study subjects lived or worked in houses with signs of mold growth or moisture problems.

Quantitative levels of viable molds were determined in air (31, 35, 6165, 67, 69, 70, 72, 73, 82) and dust (59, 62, 67, 84). Individual samples were collected for each study subject on single (31, 82, 84) or repeated occasions at home (73). In studies of workplace exposures, a limited number of measurements frequently characterized exposure conditions common to several workers (between 2,369 workers/14 samples (67) and 109 workers/24 samples (70)); however, individual sampling was also used (62). One study used personal sampling (62), while the others relied on stationary sampling. Sampling time varied from 2 minutes (70) to 6 hours (35).

The average concentration of total viable molds ranged from 32 CFU/m3 (67) to 1,480 CFU/m3 (61) when measured in air and between 33 CFU/30 mg (67) and 910 CFU/30 mg (59) when measured in dust. Some studies also reported total airborne mold counts (viable and nonviable) ranging from 6 x 103/m3 to 35 x 103/m3 (31, 35).

ß-(1,3)-D-glucan level was measured in a single study (70). Others determined the presence of specific mold species in air or on building structures (35, 6164, 73, 75, 84).

Health effects

Asthma. Cases of asthma were defined by a clinical examination (75, 83, 84) or as physician-diagnosed asthma reported by the study subjects (74, 76, 81). A change in peak expiratory flow with reference to mold exposure in patients with known asthma was the outcome measure in one study (73), while others examined peak flow variability or assessed bronchial hyperresponsiveness by decline in forced expiratory volume in 1 second (FEV1) following methacholine inhalation, according to established criteria (31, 80).

Asthma-related symptoms were defined by using validated questionnaire criteria (31, 80) or were based on self-reports of wheeze or chest tightness, usually as one of several symptoms screened for (61, 63, 66, 74, 76, 78, 82). The prevalence of asthmatic symptoms varied. For example, in the United Kingdom, 10 percent reported wheezing within 14 days (82), while 21 percent of day care workers in Finland reported wheezing within 12 months (66).

Rhinitis and nasal symptoms. Different combinations of nasal symptoms such as congestion, discharge, irritation, itching, sneezing, or dryness or self-reported rhinitis were often included among the health effects assessed (35, 5961, 64, 66, 6971, 77, 81, 82). In Finland, 11–14 percent reported nasal dryness, congestion, or discharge during a 12-month period (66); in Sweden, 54 percent reported nasal catarrh, itching, sneezing, or obstruction during 1 week (35).

Measurement of eosinophilic cationic protein, myeloperoxidase, lysozyme, and albumin in nasal mucosa and measures of nasal patency by acoustic rhinometry were used in two studies (35, 64). Tumor necrosis factor alpha, interleukin-6, nitric oxide, inducible nitric oxide synthase, and cell differential counts in nasal lavage were measured in another study (72).

Other symptoms. Most occupational studies and some of the studies focusing on home exposures collected information on a variety of throat, eye, and skin symptoms and on different general symptoms. In the studies reviewed, more than 40 different symptoms were reported; often, different studies reported different symptoms for the same organ. Frequent symptoms were eye irritation, tiredness, and headache, which often affected more than 50 percent of the subjects.

Confounders

Atopy was controlled for in several studies (62, 64, 66, 68, 71, 77, 79, 81) and house dust mites in the indoor environment in others (31, 62). In numerous studies, analyses were adjusted by gender, age, smoking, pets at home, social status, educational level, number of cohabitants, temperature, type of dwelling, ventilation, psychosocial index, stress, or job satisfaction. However, in others, confounder control was limited (e.g., no control for smoking) (59, 69, 72, 73, 75, 78, 84).

Exposure-response relation

Generally, studies that measured mold levels also assessed possible exposure-response relations by using logistic regression analysis or by computing correlation coefficients; however, this procedure was not used by all (69, 72, 73, 84), or analyses were conducted on a building level and not an individual level (59). Some studies relying on qualitative exposure data classified exposure in high and low categories from the extent of mold growth or dampness observed (66, 71, 83). Nonetheless, these classifications were not validated by mold counts.

Quality assessment

The summary quality scores are presented for each study in tables 2 and 3. Studies that used a combination of self-reported and objective exposure or outcome information were given a combined quality score to reflect this fact. A maximum of eight points was possible. Two studies were scored with the observed maximum of six points (31, 64), while the median was three points.


    EXPOSURE-EFFECT RELATIONS
 TOP
 INTRODUCTION
 INDOOR MOLDS IN NONINDUSTRIAL...
 LITERATURE SEARCH AND STUDY...
 CASE AND CLUSTER REPORTS
 ANALYTICAL STUDIES
 EXPOSURE-EFFECT RELATIONS
 DISCUSSION
 REFERENCES
 
Asthma

Signs of mold growth or dampness. Clinically verified cases of asthma, as well as self-reported cases of physician-diagnosed asthma, were associated with signs of mold growth or dampness (weighted average odds ratio = 1.48, 95 percent confidence interval (CI): 1.32, 1.65) (7476, 81, 83). This was also the case for asthma-related symptoms (weighted average odds ratio = 1.62, 95 percent CI: 1.54, 1.71) (60, 66, 74, 76, 80) (table 4). No consistent differences were found if exposure characterization was based on self-reports or reviewers’ observations. Martin et al. reported no association with asthma-related symptoms but did not present the estimates (78). Norbäck et al. showed a strong crude association with wheeze/whistling in the chest, attacks of shortness of breath, or nighttime awakening because of breathlessness/tightness in the chest (80). However, if these three sets of asthma-related symptoms were analyzed separately, no associations were observed for the latter two. Williamson observed increasing asthma severity by extent of visible mold growth (83). Bronchial hyperresponsiveness, as measured by methacoline provocation or peak flow variability, showed no association with signs of mold or dampness in the dwellings (80) (table 4).


View this table:
[in this window]
[in a new window]
 
TABLE 4. Reported relations between mold exposure in nonindustrial workplaces or dwellings and physician-diagnosed asthma, asthma-related symptoms, and bronchial hyperresponsiveness in adults: results of epidemiologic studies, 1988–1997
 
Viable mold counts. Measures of bronchial hyperresponsiveness or asthma-related symptoms were unrelated to counts of viable molds in air or dust (table 4). Only Platt et al. (82) reported estimates of the association, and a meta-measure was not computed.

Total mold counts. The single study that assessed the impact of total airborne molds (viable and nonviable) showed no associations with bronchial hyperresponsiveness or asthma-related symptoms (31) (table 4).

Rhinitis and nasal symptoms

Signs of mold growth or dampness. Nasal symptoms (congestion, discharge, irritation, itching, sneezing, or dryness) or self-reported rhinitis was associated with signs of mold growth or dampness in several studies (35, 60, 66, 77, 81) but not all (71) (table 5). A weighted average odds ratio of 1.84 was computed (95 percent CI: 1.65, 2.04).


View this table:
[in this window]
[in a new window]
 
TABLE 5. Reported relations between mold exposure in nonindustrial workplaces or dwellings and throat, eye, nose, and skin symptoms, general symptoms, or mixed-organ symptoms: results of epidemiologic studies, 1987–2000*
 
Viable mold counts. Levels of viable molds in air or dust were associated with nasal symptoms in three studies (59, 61, 70), but this was not the case in the other three (64, 69, 82) (table 5).

Total mold counts. No statistically significant association was reported between total mold counts and nasal symptoms of congestion, discharge, itching, or sneezing (64) (table 5).

ß-(1,3)-D-glucan levels. Wan and Li observed no association between ß-(1,3)-D-glucan level and nasal symptoms (70) (table 5).

Rhinometric or nasal lavage parameters. None of four rhinometric parameters of nasal patency was related to signs of dampness, but a statistically significant higher lysozyme level in nasal mucosa was observed in employees of damp buildings compared with dry buildings (p = 0.002); however, this was not found for eosinophilic cationic protein, myelo-peroxidase, or albumin levels (35). Airborne level of total molds (viable and nonviable) was related to nasal patency expressed as the sum of the volumes of the two nasal cavities measured 23–54 mm from the nasal openings but not if measured from 0 mm to 22 mm or if nasal health was examined as the minimal cross-sectional areas of the nasal cavities or as four mucosa parameters (myeloperoxidase, eosinophilic cationic protein, lysozyme, or albumin) (64). Nasal lavage concentrations of interleukin-6 and nitric oxide fell during summer vacation and rose to previous levels in workers of a school with visible mold growth, but this pattern was not seen for tumor necrosis factor alpha and cell differential count (72).

Throat, eye, and skin symptoms and general symptoms

Signs of mold growth or dampness. Consistent associations were found between signs of mold growth or dampness and throat symptoms (soreness, hoarseness, cough, dryness, irritation, or itching), eye symptoms (irritation, dryness, itching, soreness, redness, or swollen eyelids), skin symptoms (dryness, irritation, itching, rash, blushing, or eczema), and general symptoms (headache, fatigue, malaise, nausea, fever and chills, vomiting, and diarrhea) (table 5). Weighted average odds ratio values of 2.06 (95 percent CI: 1.84, 2.29), 1.73 (95 percent CI: 1.63, 1.82), 1.81 (95 percent CI: 1.55, 2.06), and 1.51 (95 percent CI: 1.44, 1.58), respectively, were computed. However, no strong associations were seen for case definitions based on combinations of nose or throat symptoms, lower respiratory tract symptoms, or wider case definitions in accordance with sick building syndrome.

Viable mold counts. No consistent pattern indicating increased occurrence of symptoms affecting the throat, eyes, or skin or of general symptoms by measured levels of viable molds in air or dust was apparent (table 5).

Total mold counts. The single study that assessed total mold levels reported no association with nasal, throat, or lower respiratory tract symptoms (62). Another study measured total mold levels but presented no results (35) (table 5).

ß-(1,3)-D-glucan levels. A statistically significant association was found between ß-(1,3)-D-glucan level and lethargy or fatigue but not for symptoms affecting the throat, eyes, or skin (70) (table 5).

Study quality and exposure effect relations

No consistent trend in odds ratios (or other measures of association) was found for asthma, asthma-related symptoms, or nose, throat, eye, or skin symptoms or for general symptoms by study quality score in the four exposure categories (signs of mold growth or dampness, viable molds, total molds, or ß-(1,3)-d-glucan). There were indications of an overall trend toward weaker or no association by increasing quality score if the four exposure categories were disregarded. However, this comparison was weakened by many negative higher-quality studies that did not report exposure effect estimates.

Health effects related to specific mold species

An increased occurrence of airway symptoms was reported in office workers from a building in which Alternaria was detected (odds ratio = 4.2, 95 percent CI: 1.1, 16.2), but symptoms were unrelated to Aspergillus, Cladosporium, and Penicillium species (62). The presence of Aspergillus species (detection level, 30 CFU/m3) was related to decreased nasal patency, whereas the presence of Penicillium species was associated with increased patency and no association was found for yeasts (64). Airborne levels of Aspergillus species showed statistically significant associations with nasal congestion, cough, phlegm, lethargy, and fatigue, but this was not the case for levels of Penicillium and Cladosporium species or yeast in day care workers (61). No significant difference in pulmonary complaints related to levels of Penicillium, Alternaria, and Aspergillus species was reported in another study (73).

Allergy as a possible mode of action

A positive skin prick test for Alternaria species was associated with work-related respiratory symptoms and growth of Alternaria species at the worksite, but no such relation was suggested for Cladosporium and Penicillium species (62). However, specific immunoglobulin E to Alternaria alternata was not more frequent in asthma patients with signs of mold growth at home than in asthma patients without such mold growth, but this finding was true for Penicillium notatum (75). Indoor mold levels or signs of indoor mold growth were unrelated to positive skin prick tests for common molds (84). Total immunoglobulin E and s-eosinophilic cationic protein were related to mold levels (31). Indicators of atopy did not modify an observed association between signs of mold growth and lower respiratory tract symptoms, which would be expected if allergy is of causal importance (76).


    DISCUSSION
 TOP
 INTRODUCTION
 INDOOR MOLDS IN NONINDUSTRIAL...
 LITERATURE SEARCH AND STUDY...
 CASE AND CLUSTER REPORTS
 ANALYTICAL STUDIES
 EXPOSURE-EFFECT RELATIONS
 DISCUSSION
 REFERENCES
 
The analytical studies reviewed provide strong evidence that signs of mold growth or dampness in nonindustrial workplaces or dwellings are associated with asthma as diagnosed by a physician or on the basis of relevant symptoms and with nose, eye, and skin symptoms; fatigue; or headache. However, no consistent associations were found for objective measures of bronchial hyperresponsiveness or nasal mucosal parameters, but the studies were few (35, 64, 80). In children, asthma also has been related to signs of mold growth or dampness (18, 19).

The studies provide no consistent evidence that quantitative measures of total or viable indoor molds, ß-(1,3)-D-glucan, or specific mold species are associated with asthma disease, asthma-related symptoms, or bronchial hyperresponsiveness. These findings are in line with the fact that the impact of mold exposure on asthma in adults is largely unknown (85), even if single cases of occupational mold asthma have been reported (11, 12). In addition, nose, throat, eye, and skin symptoms; fatigue; headache; or objective nasal parameters were not associated with specific measures of fungal biomass.

The discrepancies in these results may suggest that the quantitative measures of mold exposure were inappropriate, that detection levels in the quantitative studies were insufficient, or that these studies were flawed because of bias. The latter aspect also pertains to the studies relying on qualitative signs of mold growth or dampness. We discuss these aspects one at a time.

Appropriateness of quantitative measures of mold exposure

In the studies reviewed, four principally different measures of molds in air or dust were used: total viable mold counts, total mold counts (viable and nonviable), ß-(1,3)-D-glucan level, and specific mold species (qualitative or quantitative). Air and dust are the media relevant to examine; dermal absorption or ingestion of surface-contaminated material is not expected to play a significant role, and no difference in exposure-effect relations was observed when exposure assessment was based on air or dust samples.

However, one may question the appropriateness of using viable mold counts as the measure of exposure since higher levels generally are not observed in buildings characterized by mold growth or water damage compared with nonproblem buildings or outdoor air (21, 23, 25, 30, 3537). This question may also apply to total mold counts; however, for this measure, data are limited. ß-(1,3)-D-glucan levels have been associated with signs of mold growth in the indoor environment (70).

Thus, it may be that the measures of exposure applied do not provide a sufficient characterization of mold exposure. On the other hand, they all reflect the extent of molds from recent and current sources in air or dust and are therefore expected to relate to human health effects if a causal effect of indoor molds is present.

Even if molds are obvious causal candidates for the health effects reported by subjects working or living in buildings with signs of mold growth or dampness, there are also other candidates, for example, house dust mites. House dust mites, similar to molds, prefer a humid environment and are well-documented causes of allergic airway disease. Furthermore, house dust mites were related to asthmatic symptoms in the study by Björnsson et al. (in contrast to mold counts) (31) but not in the study by Wan and Li (70). Inhalation of bacterial particles could also, at least partly, explain some of the symptoms, since endotoxin exposure determines the severity of asthma in people allergic to house dust mites (86); however, the studies reviewed do not provide consistent evidence for this hypothesis (31, 61, 64, 70).

Detection level of the quantitative studies

The lack of any consistent association between levels of mold exposure and health effects may be due to nondifferential misclassification, since a limited number of mold measurements often were used to classify exposure levels for several workers in large buildings (61, 6365, 67) or sampling time was brief (70). This limitation may have attenuated real associations, since mold levels show significant variability (25).

If there is a threshold level for mold-related health effects, it may be that the populations in the quantitative studies were exposed below this level. However, no stronger exposure-effect associations were seen in the few studies reviewed with the highest average exposure levels (>1,000 CFU/m3) (61, 73).

Bias in the quantitative studies

It is expected that subjects with mucosal or respiratory symptoms take precautions to avoid exposures in their dwellings or leave workplaces that have mold and moisture problems. Thus, in cross-sectional studies, which was the preferred design of all but two of the studies reviewed, a possible relation between mold exposure and health effects may be underestimated (87). However, since it is expected that such selection bias would affect studies classifying exposure according to signs of mold growth more than those relying on quantitative measures, this possibility can hardly explain the discrepancy in the results of the studies reviewed. It is also unlikely with respect to other aspects of study quality, because no systematic deficit in overall quality (design, participation, confounder control, exposure-effect assessment, outcome specificity) was seen for the quantitative studies compared with those relying on qualitative exposure data.

Discrepancies in results could also be seen if generally lower exposure levels were found compared with the qualitative studies. However, this possibility was not supported by the two studies by Björnsson et al. and Norbäck et al. that characterized the same population by both qualitative and quantitative exposure information (31, 80).

Bias in the qualitative studies

The major limitation of the reviewed studies relying on self-reports of exposure is the inherent risk of information bias. Pirhonen et al. illustrated this limitation by observing that associations between self-reported home exposures and symptoms disappeared when subjects who had symptoms that could hardly be explained by indoor exposures were excluded from the analyses (81). Others have provided strong evidence of a significant effect of recall bias in studies of health effects due to indoor climate (22, 88), but not all have (82). Researchers’ independent observations of indoor mold growth may to some extent counter this bias, but not in studies with symptoms as the health outcome; symptoms, by definition, are self-reported, and mold growth visible to surveyors is also expected to be visible to study subjects. The studies that relied on reviewers’ observations of exposure showed results comparable to those relying on self-reports.

Case and cluster reports

A high proportion of the studies reviewed were initiated because of concerns about mold-related health effects in the study populations. These studies may generate important hypotheses. However, they do not form a solid basis for assessing causal effects (89), even if an external, nonexposed reference population is included (39, 40, 50, 51, 54, 56, 57). Thus, in this review, these studies were considered less important than the analytical studies.

On the other hand, these studies may provide important information from extreme exposure situations rarely encountered in systematic studies. The reports by Bernstein et al. and Kolmodin et al. of cases of organic dust toxic syndrome (now known as toxic pneumonitis or inhalation fever) and allergic alveolitis following high-level airborne mold exposure (5 x 103 CFU/m3 and 106 CFU/m3, respectively) (43, 45) are in accordance with cause-effect relations well documented among farmers and in cases of exposure to humidifiers highly contaminated by microbes (9, 10).

A possible mode of action

If increased levels of molds in indoor environments cause the respiratory and mucosal health effects suggested, immunoglobulin E–mediated allergy is a possible mechanism. However, no consistent support for this mechanism was provided by the few studies that included information on mold exposure, health effects, and skin prick test results or mold-specific immunoglobulin E.

ß-(1,3)-glucan induces nonspecific inflammatory reactions (6). Lethargy and fatigue were the only symptoms that showed an association with ß-(1,3)-glucan level. However, this association was weak and was reported in only a single study.

Mycotoxins have been detected in buildings in which persons have complained about a sick building. However, reported health effects from this exposure have not been disentangled from other possible causes in the indoor environment (39, 40, 47), and none of the systematic studies reviewed specifically examined mycotoxins.

Overall, we conclude that the weight of evidence indicates that exposure to exceptionally high mold levels may cause allergic alveolitis and inhalation fever, and this finding may also pertain to buildings severely damaged by extensive and prolonged mold growth. However, the studies we reviewed provide no evidence that increasing levels of viable mold exposure in nonindustrial work environments or dwellings are related to an increasing occurrence of asthma or to nose, eye, and skin symptoms; fatigue; or headache in the adult population, which may be due to inappropriate or insufficient measures of mold exposure. No consistent indications were presented that related total fungal biomass to health effects; however, the studies were few.

Even if the epidemiologic database is insufficient to judge whether mold exposure in nonindustrial environments has adverse health effects on adults, we recommend that workplaces be kept clean, well maintained, and dry. Nonetheless, we will be cautious before ascribing asthma; nose, eye, and skin symptoms; fatigue; or headache to mold exposure in our patients’ nonindustrial workplaces.

However, these health problems more often are reported by adults working or living in buildings that have signs of indoor mold growth and dampness. To elucidate possible causal mechanisms, further studies should probably focus on populations experiencing larger mold exposure contrasts than those encountered in nonindustrial environments. Alternative measures are recommended to characterize buildings that have signs of mold growth and dampness. They may relate to molds and their metabolic products such as mycotoxins, but other factors should also be considered, as well as more appropriate exposure assessment strategies. Newly developed objective methods to determine inflammation, such as acoustic rhinometry, nasal lavage, tear fluid sampling, induced sputum, and condensed breath, will be needed in order to study exposure-response relations and to avoid reporting bias in this area of low exposure. The low exposure situation also leads to the need for good control for confounders and exposures outside the buildings studied.


    FOOTNOTES
 
Reprint requests to Dr. Henrik Kolstad, Department of Occupational Medicine, Aarhus University Hospital, Norrebrogade 44, DK-8000 Aarhus C, Denmark (e-mail: hkols{at}akh.aaa.dk). Back


    REFERENCES
 TOP
 INTRODUCTION
 INDOOR MOLDS IN NONINDUSTRIAL...
 LITERATURE SEARCH AND STUDY...
 CASE AND CLUSTER REPORTS
 ANALYTICAL STUDIES
 EXPOSURE-EFFECT RELATIONS
 DISCUSSION
 REFERENCES
 

  1. Menzies D, Bourbeau J. Building-related illnesses. N Engl J Med 1997;337:1524–31.[Free Full Text]
  2. Flannigan B, McCabe EM, McGarry F. Allergenic and toxigenic micro-organisms in houses. Soc Appl Bacteriol Symp Ser 1991;20:61S–73S.[Medline]
  3. Pieckova E, Jesenska Z. Microscopic fungi in dwellings and their health implications in humans. Ann Agric Environ Med 1999;6:1–11.[Medline]
  4. Barbee RA, Lebowitz MD, Thompson HC, et al. Immediate skin-test reactivity in a general population sample. Ann Intern Med 1976;84:129–33.[ISI][Medline]
  5. Nielsen NH, Svendsen UG, Madsen F, et al. Allergen skin test reactivity in an unselected Danish population. The Glostrup Allergy Study, Denmark. Allergy 1994;49:86–91.[ISI][Medline]
  6. Rylander R, Lin R. (1–>3)-beta-D-glucan—relationship to indoor air-related symptoms, allergy and asthma. Toxicology 2000;152:47–52.[CrossRef][ISI][Medline]
  7. Czop JK, Austen KF. A beta-glucan inhibitable receptor on human monocytes: its identity with the phagocytic receptor for particulate activators of the alternative complement pathway. J Immunol 1985;134:2588–93.[Abstract]
  8. Douwes J, van der Sluis B, Doekes G, et al. Fungal extracellular polysaccharides in house dust as a marker for exposure to fungi: relations with culturable fungi, reported home dampness, and respiratory symptoms. J Allergy Clin Immunol 1999;103:494–500.[CrossRef][ISI][Medline]
  9. Richardson HB. Hypersensitivity pneumonitis. In: Rylander R, Jacobs RR, eds. Organic dusts. Exposure, effects, and prevention. Boca Raton, FL: Lewis Publishers, 1998:139–61.
  10. Rask-Andersen A. Inhalation fever. In: Harber P, Schenker MB, Balmes JR, eds. Occupational and environmental respiratory disease. St. Louis, MO: Mosby, 1996:243–58.
  11. Klaustermeyer WB, Bardana EJ Jr, Hale FC. Pulmonary hypersensitivity to Alternaria and Aspergillus in baker’s asthma. Clin Allergy 1977;7:227–33.[CrossRef][ISI][Medline]
  12. Cote J, Chan H, Brochu G, et al. Occupational asthma caused by exposure to neurospora in a plywood factory worker. Br J Ind Med 1991;48:279–82.[ISI][Medline]
  13. Delfino RJ, Coate BD, Zeiger RS, et al. Daily asthma severity in relation to personal ozone exposure and outdoor fungal spores. Am J Respir Crit Care Med 1996;154:633–41.[Abstract]
  14. Austwick PK. Mycotoxins. Br Med Bull 1975;31:222–9.[Free Full Text]
  15. Etzel RA, Montana E, Sorenson WG, et al. Acute pulmonary hemorrhage in infants associated with exposure to Stachybotrys atra and other fungi. Arch Pediatr Adolesc Med 1998;152:757–62.[Abstract/Free Full Text]
  16. From the Centers for Disease Control and Prevention. Update: pulmonary hemorrhage/hemosiderosis among infants—Cleveland, Ohio, 1993–1996. JAMA 2000;283:1951–3.[Free Full Text]
  17. Husman T. Health effects of indoor-air microorganisms. Scand J Work Environ Health 1996;22:5–13.[ISI][Medline]
  18. Verhoeff AP, Burge HA. Health risk assessment of fungi in home environments. Ann Allergy Asthma Immunol 1997;78:544–56.[ISI][Medline]
  19. Peat JK, Dickerson J, Li J. Effects of damp and mould in the home on respiratory health: a review of the literature. Allergy 1998;53:120–8.[ISI][Medline]
  20. Niemeijer NR, de Monchy JG. Age-dependency of sensitization to aero-allergens in asthmatics. Allergy 1992;47:431–5.[ISI][Medline]
  21. Strom G, Palmgren U, Wessen B, et al. The sick building syndrome. An effect of microbial growth in building constructions? Indoor Air 1990;1:173–8.[CrossRef]
  22. Dales RE, Miller D, McMullen E. Indoor air quality and health: validity and determinants of reported home dampness and moulds. Int J Epidemiol 1997;26:120–5.[Abstract/Free Full Text]
  23. Miller JD, Haisley PD, Reinhardt JH. Air sampling results in relation to extent of fungal colonization of building materials in some water-damaged buildings. Indoor Air 2000;10:146–51.[CrossRef][ISI][Medline]
  24. Dillon HK, Miller JD, Sorenson WG, et al. Review of methods applicable to the assessment of mold exposure to children. Environ Health Perspect 1999;107(suppl 3):473–80.
  25. Verhoeff AP, van Wijnen JH, Brunekreef B, et al. Presence of viable mould propagules in indoor air in relation to house damp and outdoor air. Allergy 1992;47:83–91.[ISI][Medline]
  26. Verhoeff AP, van Reenen-Hoekstra ES, Samson RA, et al. Fungal propagules in house dust. I. Comparison of analytic methods and their value as estimators of potential exposure. Allergy 1994;49:533–9.[ISI][Medline]
  27. Palmgren U, Strom G, Blomquist G, et al. Collection of airborne micro-organisms on Nuclepore filters, estimation and analysis—CAMNEA method. J Appl Bacteriol 1986;61:401–6.[Medline]
  28. Douwes J, Doekes G, Montijn R, et al. Measurement of beta(1–>3)-glucans in occupational and home environments with an inhibition enzyme immunoassay. Appl Environ Microbiol 1996;62:3176–82.[Abstract]
  29. Miller JD, Young JC. The use of ergosterol to measure exposure to fungal propagules in indoor air. Am Ind Hyg Assoc J 1997;58:39–43.[ISI][Medline]
  30. Garrett MH, Rayment PR, Hooper MA, et al. Indoor airborne fungal spores, house dampness and associations with environmental factors and respiratory health in children. Clin Exp Allergy 1998;28:459–67.[CrossRef][ISI][Medline]
  31. Björnsson E, Norbäck D, Janson C, et al. Asthmatic symptoms and indoor levels of micro-organisms and house dust mites. Clin Exp Allergy 1995;25:423–31.[CrossRef][ISI][Medline]
  32. Hyvärinen A, Reponen T, Husman T, et al. Characterizing mold problem buildings—concentration and flora of viable fungi. Indoor Air 1993;3:337–43.
  33. Dharmage S, Bailey M, Raven J, et al. Prevalence and residential determinants of fungi within homes in Melbourne, Australia. Clin Exp Allergy 1999;29:1481–9.[CrossRef][ISI][Medline]
  34. Hunter CA, Grant C, Flannigan B, et al. Mould in buildings: the air spora of domestic dwellings. Int Biodeterior 1988;24:81–101.
  35. Wieslander G, Norback D, Nordstrom K, et al. Nasal and ocular symptoms, tear film stability and biomarkers in nasal lavage, in relation to building-dampness and building design in hospitals. Int Arch Occup Environ Health 1999;72:451–61.[CrossRef][ISI][Medline]
  36. Holmberg K. Health risks of exposure to fungal infections in construction workers. (In Swedish). Lakartidningen 1984;81:3327–33.[Medline]
  37. Li CS, Hsu LY. Airborne fungus allergen in association with residential characteristics in atopic and control children in a subtropical region. Arch Environ Health 1997;52:72–9.[ISI][Medline]
  38. Rautiala S, Reponen T, Hyvarinen A, et al. Exposure to airborne microbes during the repair of moldy buildings. Am Ind Hyg Assoc J 1996;57:279–84.[ISI][Medline]
  39. Hodgson MJ, Morey P, Leung WY, et al. Building-associated pulmonary disease from exposure to Stachybotrys chartarum and Aspergillus versicolor. J Occup Environ Med 1998;40:241–9.[CrossRef][ISI][Medline]
  40. Johanning E, Biagini R, Hull DL, et al. Health and immunology study following exposure to toxigenic fungi (Stachybotrys chartarum) in water-damaged office environment. Int Arch Occup Environ Health 1996;68:207–18.[ISI][Medline]
  41. Greenland S. Meta-analysis. In: Rothman KJ, Greenland S, eds. Modern epidemiology. 2nd ed. Philadelphia, PA: Lippincott Williams & Wilkins, 1998:643–73.
  42. Thorn A, Lewne M, Belin L. Allergic alveolitis in a school environment. Scand J Work Environ Health 1996;22:311–14.[ISI][Medline]
  43. Bernstein RS, Sorenson WG, Garabrant D, et al. Exposures to respirable, airborne Penicillium from a contaminated ventilation system: clinical, environmental and epidemiological aspects. Am Ind Hyg Assoc J 1983;44:161–9.[ISI][Medline]
  44. Fergusson RJ, Milne LJ, Crompton GK. Penicillium allergic alveolitis: faulty installation of central heating. Thorax 1984;39:294–8.[Abstract]
  45. Kolmodin Hedman B, Blomquist G, Sikstrom E. Mould exposure in museum personnel. Int Arch Occup Environ Health 1986;57:321–3.[CrossRef][ISI][Medline]
  46. Rose CS, Martyny JW, Newman LS, et al. "Lifeguard lung": endemic granulomatous pneumonitis in an indoor swimming pool. Am J Public Health 1998;88:1795–800.[Abstract/Free Full Text]
  47. Croft AC, Jarvis B, Yatawara CS. Airborne outbreak of trichothecene toxicosis. Atmospher Environ 1986;20:549–52.[CrossRef]
  48. Auger PL, Gourdeau P, Miller JD. Clinical experience with patients suffering from a chronic fatigue-like syndrome and repeated upper respiratory infections in relation to airborne molds. Am J Ind Med 1994;25:41–2.[ISI][Medline]
  49. Noble JA, Crow SA, Ahearn DG, et al. Allergic fungal sinusitis in the southeastern USA: involvement of a new agent Epicoccum nigrum Ehrenb. ex Schlecht. 1824. J Med Vet Mycol 1997;35:405–9.[ISI][Medline]
  50. Rylander R. Airborne (1-3)-ß-D-glucan and airway disease in a day-care center before and after renovation. Arch Environ Health 1997;52:281–5.[ISI][Medline]
  51. Thorn J, Rylander R. Airways inflammation and glucan in a rowhouse area. Am J Respir Crit Care Med 1998;157:1798–803.
  52. Malkin R, Martinez K, Marinkovich V, et al. The relationship between symptoms and IgG and IgE antibodies in an office environment. Environ Res 1998;76:85–93.[Medline]
  53. Larsen FO, Meyer HW, Ebbehøj N, et al. Are fungi-specific IgE found in staff suffering from nonallergic sick building syndrome? Inflamm Res 1997;46(suppl 1):S79–80.
  54. Hodgson MJ, Morey PR, Simon JS, et al. An outbreak of recurrent acute and chronic hypersensitivity pneumonitis in office workers. Am J Epidemiol 1987;125:631–8.[Abstract/Free Full Text]
  55. Cooley JD, Wong WC, Jumper CA, et al. Correlation between the prevalence of certain fungi and sick building syndrome. Occup Environ Med 1998;55:579–84.[Abstract]
  56. Harrison J, Pickering CA, Faragher EB, et al. An investigation of the relationship between microbial and particulate indoor air pollution and the sick building syndrome. Respir Med 1992;86:225–35.[ISI][Medline]
  57. Waegemaekers M, van Wageningen N, Brunekreef B, et al. Respiratory symptoms in damp homes. A pilot study. Allergy 1989;44:192–8.[ISI][Medline]
  58. Rylander R, Persson K, Goto H, et al. Airborne beta-1,3-glucan may be related to symptoms in sick buildings. Indoor Air 1992;1:263–7.
  59. Gyntelberg F, Suadicani P, Nielsen JW, et al. Dust and the sick building syndrome. Indoor Air 1994;4:223–38.
  60. Li CS, Hsu CW, Lu CH. Dampness and respiratory symptoms among workers in daycare centers in a subtropical climate. Arch Environ Health 1997;52:68–71.[ISI][Medline]
  61. Li CS, Hsu CW, Tai ML. Indoor pollution and sick building syndrome symptoms among workers in day-care centers. Arch Environ Health 1997;52:200–7.[ISI][Medline]
  62. Menzies D, Comtois P, Pasztor J, et al. Aeroallergens and work-related respiratory symptoms among office workers. J Allergy Clin Immunol 1998;101:38–44.[CrossRef][ISI][Medline]
  63. Nelson NA, Kaufman JD, Burt J, et al. Health symptoms and the work environment in four nonproblem United States office buildings. Scand J Work Environ Health 1995;21:51–9.[ISI][Medline]
  64. Norback D, Walinder R, Wieslander G, et al. Indoor air pollutants in schools: nasal patency and biomarkers in nasal lavage. Allergy 2000;55:163–70.[CrossRef][ISI][Medline]
  65. Ooi PL, Goh KT, Phoon MH, et al. Epidemiology of sick building syndrome and its associated risk factors in Singapore. Occup Environ Med 1998;55:188–93.[Abstract]
  66. Ruotsalainen R, Jaakkola N, Jaakkola JJK. Dampness and molds in day-care centers as an occupational health problem. Int Arch Occup Environ Health 1995;66:369–74.[CrossRef][ISI][Medline]
  67. Skov P, Valbjorn O, Pedersen BV. Influence of indoor climate on the sick building syndrome in an office environment. The Danish Indoor Climate Study Group. Scand J Work Environ Health 1990;16:363–71.[ISI][Medline]
  68. Stenberg B, Eriksson N, Hoog J, et al. The sick building syndrome (SBS) in office workers. A case-referent study of personal, psychosocial and building-related risk indicators. Int J Epidemiol 1994;23:1190–7.[Abstract/Free Full Text]
  69. Teeuw KB, Vandenbroucke-Grauls CM, Verhoef J. Airborne gram-negative bacteria and endotoxin in sick building syndrome. A study in Dutch governmental office buildings. Arch Intern Med 1994;154:2339–45.[Abstract]
  70. Wan GH, Li CS. Indoor endotoxin and glucan in association with airway inflammation and systemic symptoms. Arch Environ Health 1999;54:172–9.[ISI][Medline]
  71. Wan GH, Li CS. Dampness and airway inflammation and systemic symptoms in office building workers. Arch Environ Health 1999;54:58–63.[ISI][Medline]
  72. Hirvonen MR, Ruotsalainen M, Roponen M, et al. Nitric oxide and proinflammatory cytokines in nasal lavage fluid associated with symptoms and exposure to moldy building microbes. Am J Respir Crit Care Med 1999;160:1943–6.[Abstract/Free Full Text]
  73. Beaumont F, Kauffman HF, Sluiter HJ, et al. Sequential sampling of fungal air spores inside and outside the homes of mould-sensitive, asthmatic patients: a search for a relationship to obstructive reactions. Ann Allergy 1985;55:740–6.[ISI][Medline]
  74. Brunekreef B. Damp housing and adult respiratory symptoms. Allergy 1992;47:498–502.[ISI][Medline]
  75. Burr ML, Mullins J, Merrett TG, et al. Indoor moulds and asthma. J R Soc Health 1988;108:99–101.[ISI][Medline]
  76. Dales RE, Burnett R, Zwanenburg H. Adverse health effects among adults exposed to home dampness and molds. Am Rev Respir Dis 1991;143:505–9.[ISI][Medline]
  77. Koskinen OM, Husman TM, Meklin TM, et al. The relationship between moisture or mould observations in houses and the state of health of their occupants. Eur Respir J 1999;14:1363–7.[Abstract]
  78. Martin CJ, Platt SD, Hunt SM. Housing conditions and ill health. BMJ (Clin Res Ed) 1987;294:1125–7.[ISI][Medline]
  79. Norbäck D, Edling C. Environmental, occupational, and personal factors related to the prevalence of sick building syndrome in the general population. Br J Ind Med 1991;48:451–62.[ISI][Medline]
  80. Norbäck D, Björnsson E, Janson C, et al. Asthmatic symptoms and volatile organic compounds, formaldehyde, and carbon dioxide in dwellings. Occup Environ Med 1995;52:388–95.[Abstract]
  81. Pirhonen I, Nevalainen A, Husman T, et al. Home dampness, moulds and their influence on respiratory infections and symptoms in adults in Finland. Eur Respir J 1996;9:2618–22.